Revision 1 2012-13CDC FOUR
57
is applied, and the output level is also -35 dB. The signal level at B is -10 dB,
which is above the threshold. This results in the output level being reduced by 13
dB to -23 dB. Real world signals, of course, have a dynamic range which includes
elements both above and below the threshold, so the effect of compression is
only for the louder elements to be reduced in level, which will reduce the overall
volume. This reduction can be compensated for with the Level control.
As with the Channel Overview page, the dynamics processing of each channel
may be viewed and compared by pressing each channel’s SEL button in turn.